-40%
FLUKE 1550C 5kV Insulation Tester, MegOhmMeter 5kV Digital Insulation Resistance
$ 1319.47
- Description
- Size Guide
Description
FLUKE 1550C 5kV Insulation Tester, MegOhmMeter 5kV Digital Insulation ResistanceFLUKE 1550C 5kV Insulation Tester, MegOhmMeter 5kV Digital Insulation Resistance
Click images to enlarge
Description
INV 2610
This unit is fresh from a decommissioned coal power plant. It didn't get much use. The protective plastic film still covers the screen. Many of the cables are still in their original packages. Guaranteed to calibrate and work as intended or return it for a refund.
Make: Fluke
Model: 1550C
Type: Insulation Tester
Serial Number: 3086016
Includes: main unit, CD, user manual, cables and cords, hard case.
FLUKE 1550C 5kV Insulation Tester, MegOhmMeter
Product Features:
Test voltages to up 5 kV
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alert for increased user safety
Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
Up to 99 memory locations
Over 750 tests between battery charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large digital/analog LCD
Capacitance and leakage current measurement
Ramp function for breakdown testing
Resistance measurements up to 2 TΩ
Timer settings up to 99 minutes
Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
Insulation test voltage accuracy: -0%, +10% at 1 mA load current
Induced AC mains current rejection: 2 mA maximum
Charging rate for capacitive load: 5 seconds per μF
Discharge rate for capacitive load1.5 s/μF
Leakage current measurement range:1 nA to 2 mA
Leakage current measurement accuracy: ±(5% + 2 nA)
Capacitance measurement range: 0.01 μF to 15.00 μF
Capacitance measurement accuracy: ±(15% rdg + 0.03 μF)
Timer range: 0 to 99 minutes
Timer resolution setting: 1 minute
Live circuit warning range: 30 V to 660 V AC/DC, 50/60 Hz
Live circuit warning voltage accuracy: ±(15% + 2 V)
Software specifications: FlukeView Forms basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8
General Specifications:
Display:75 x 105 mm
Power: 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC): 85 V to 250 V AC 50/60 Hz 20 VA
Dimensions: 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
Weight: 3.7 kg (8.2 lb)
Temperature (operating): -20°C to 50°C (-4°F to 122°F)
Temperature (storage): -20°C to 65°C (-4°F to 149°F)
Humidity: 80% to 31°C decreasing linearly to 50% at 50°C
Altitude2000 m
Enclosure sealing: IP40
Input overload protection: 1000 V AC
Electromagnetic compatibility: EN 61326
Safety compliance: IEC 61010-1: Overvoltage category II, Pollution Degree 2
IEC 61010-2-030: Measurement 600V CAT IV/1000V CAT III
IEC 61557-1, IEC 61557-2
Blue Rack
Buy with confidence. There is a 14 day return privilege if the item arrives not as described or non-functional unless otherwise stated in the description. Buyer must notify us within 14 days of items arrival. This is not a satisfaction guarantee, I will only honor a return if we miss-listed the items or it does not function properly. I try to take REALLY good photos so you know what you are bidding on. We want you to feel comfortable buying from us. If you have any questions please let us know.