-40%
Fluke 1507 Insulation Resistance Tester, 50 to 1000 V
$ 353.49
- Description
- Size Guide
Description
Untitled DocumentFluke 1507 Insulation Resistance Tester, 50 to 1000 V
Model:
1507
| Order No:
1507
Ideal for electrical contractors and industrial and commercial electricians, this insulation resistance tester also comes in a compact and rugged design and is easy to use. Additionally, this tool is great for troubleshooting, commissioning, and preventative maintenance applications.
Brand:
Fluke
Model:
1507
Order No:
1507
Condition:
NEW
Description
Fluke 1507 Insulation Resistance Tester, 50 to 1000 V
Fluke 1507 Offers
Ideal for advanced industrial and electrical insulation testing, this insulation tester comes in a compact design and features versatility. Additionally, the multiple test voltages facilitate the tool for many troubleshooting, commissioning, and preventative maintenance applications.
Take advantage of the full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and lightweight make it easy to pack and use. Additional features, like the remote probe, save both time and money, especially when performing repetitive tests.
Features
Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians
Automatically calculates polarization index and dielectric absorption ratio
Makes repetitive tests simple and easy with a compare (pass/fail) function
Offers multiple insulation test voltages: 50, 100, 250, 500, and 1000 V
Performs insulation tests from 0.01 M&ohm to 2.0 G&ohm
Includes live circuit detection to prevent insulation test if voltage >30 V is detected
Includes auto-discharge of capacitive voltage for added user protection
Measures AC/DC voltage from 0.1 to 600 V and resistance from 0.01 &ohm to 20.00 k&ohm
Provides lo-ohms earth-bond continuity (200 mA)
Simplifies repetitive or hard-to-reach testing with the remote test probe
Saves battery power with auto power off
Presents results on a large, backlit display
Features CAT IV 600 V over voltage category rating
Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
elementExists('bonus-content/fluke-1503')) {echo $this->element('bonus-content/fluke-1503');}?>
Included
Insulation Resistance Tester
Remote probe
Test leads
Test probes
Alligator clips
User documentation
Specifications
AC/DC Voltage Specifications
Range
600.0 V
Resolution
0.1 V
Accuracy
50 Hz to 400 Hz: ±(2% of rdg + 3 digits)
Input Impedance
3 MΩ (nominal), < 100 pF
Common Mode Rejection Ratio (1 kΩ unbalanced)
>60 dB at DC, 50 or 60 Hz
Overload Protection
600 V RMS or DC
Earth Bond Resistance Specifications
Range
20.00 &ohm to 20.00 k&ohm
Resolution
0.01 &ohm to 0.01 k&ohm
Accuracy
±(1.5% + 3 digits)
Overload Protection
2 V RMS or DC
Open Circuit Test Voltage
>4.0 V, <8 V
Short Circuit Current
>200.0 mA
Insulation Specifications
Measurement Range
0.01 M&ohm to 10 G&ohm
Test Voltage
50, 100, 250, 500, 1000 V
Test Voltage Accuracy
+20%, -0%
Short Circuit Current
1 mA nominal
Auto Discharge
Discharge time <0.5 second for C = 1 µF or less
Live Circuit Indicator
Inhibit test if terminal voltage >30 V prior to initialization of test
Maximum Capacitive Load
Operable with up to 1 µF load
Live Circuit Detection
Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum Capacitive Load
Operable with up to 1 µF load
Measure Accuracy
50 V: ±(3% + 5)
100 V: ±(3% + 5)
250 V: ±(3% + 5)
500 V: ±(3% + 5)
1000 V: ±(3% + 5) to 2000 M&ohm, ±(10% + 3) above 2000 M&ohm
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.